Fluke FLUKE-115 Electricians True-RMS Digital Multimeter 600V
Features:
For general purpose electrical and electronic test requirements, the Fluke 115 True RMS digital multimeter provides the perfect answer
Its simple, one-handed operation and compact design meets the needs of a wide variety of field service technicians
It measures True RMS voltage and current with 6000 count resolution as well as resistance, continuity, frequency and capacitance for quick verifications
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V environments
General purpose digital multimeter for electrical and electronic testing
Ideal for quick verifications and field service
Presents a large white LED backlight for working in poorly lit areas
Measures AC and DC voltage to 600V
Measures AC and DC current to 10A (20 A overload for 30-seconds max)
Specifications:
Maximum voltage between any terminal and earth ground: 600 V
Surge protection: 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Display: Digital: 6,000 counts, updates 4 per second
Bar graph: 33 segments, updates 32 per second
Operating temperature: -10°C to + 50°C
Storage temperature: -40°C to + 60°C
Battery type: 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life: 400 hours typical, without backlight
DC millivolts: Range/resolution: 600.0 mV / 0.1 mV | Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
DC volts: Range/resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.00 V / 0.1 V | Accuracy: ± ([% of reading] + [counts]): 0.5% + 2
AC millivolts: True RMS: Range/resolution: 600.0 mV / 0.1 mV | Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
AC volts True RMS: Range/resolution: 6.000 V / 0.001 V, 60.00 V / 0.01 V, 600.0 V / 0.1 V | Accuracy: 1.0% + 3 (DC, 45 Hz to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
Continuity: Range/resolution: 600 Ω / 1 Ω | Accuracy: Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms: Range/resolution: 600.0 Ω / 0.1 Ω, 6.000 kΩ / 0.001 kΩ, 60.00 kΩ / 0.01 kΩ, 600.0 kΩ / 0.1 kΩ, 6.000 MΩ / 0.001 MΩ | Accuracy: 0.9% + 1 | Range/resolution: 40.00 MΩ / 0.01 MΩ | Accuracy: 5% + 2
Diode test: Range/resolution 2.00 V / 0.001 V | Accuracy 0.9% + 2
Capacitance: Range/resolution: 1000 nF / 1 nF, 10.00 μF / 0.01 μF, 100.0 μF / 0.1 μF, 9999 μF / 1 μF, 100 μF to 1000 μF | Accuracy: 1.9% + 2 | Range/resolution: > 1000 μF | Accuracy: 5% + 20%
Lo-Z capacitance: Range: 1 nF to 500 μF | Accuracy: 10% + 2 typical
AC amps True RMS (45 Hz to 500Hz): Range/resolution: 6.000 A / 0.001 A,10.00 A / 0.01 A | Accuracy: 1.5% + 3, 20 A overload for 30-seconds max
DC amps: Range/resolution: 6.000 A / 0.001 A, 10.00 A / 0.01 A | Accuracy: 1.0% + 3, 20 A overload for 30-seconds max
Hz (V or A input): Range/resolution: 99.99 Hz / 0.01 Hz, 999.9 Hz / 0.01 Hz, 9.999 kHz / 0.001 kHz, 50 kHz / 0.01 kHz | Accuracy: 0.1% + 2
Delivery
For all orders up to 20kg and no longer than 1m to be delivered to regional and interstate areas, we use Australia Post and StarTrack Express with tracking provided sent to you via email.
For all orders above 20kg, we use StarTrack Express and Hunter Express.
All deliveries can be tracked online at all times via the shipping providers online tracking service.
Visit: www.auspost.com.au/track/ for Australia post tracking and enter tracking number given per order.
Visit: www.tntexpress.com.au/interaction/trackntrace.aspx for TNT Express tracking and enter tracking number given per order.
You will be notified as soon as your order is dispatched.
We will notify you by email or telephone in the event that:
- We are unable to deliver your order within the allocated time
- We are unable to fulfill your order
Delivery Times
If your order contains some items that are not listed as "in stock", we will dispatch the complete order once everything contained in the order has arrived in stock. This will normally take 2-10 working days. Should lead times be more than 10 working days we will contact you via e-mail or telephone.
Next day dispatch is defined as the next working day following your order placed between 8am and 3pm.
All orders received after 5pm Friday or on weekends will be dispatched the following Monday for delivery on Tuesday.
All orders will require a signature upon delivery in most cases unless 'authority to leave' is stated in the comments section of the order to pass this onto our shipping provider. In the event that the customer being absent when delivery is attempted, a card will be left detailing the drivers actions. The card will also contain details on how to arrange to collect from the local parcel company depot.
We do not authorise re-deliveries. Someone must be at the delivery address to sign and receive for the goods and answer the phone call from the courier company to arrange this. If you require a re-delivery, there will be an additional charge requested from the shipping provider.
Our carrier also offers a pallet delivery sevice for bulky orders. Please ensure that you have an appropriate offload facility for the receiving of pallets. There may be a surcharge for bulky orders. If so, we will contact you before we dispatch your order.
We recommend that you inspect the goods prior to signing for delivery. If you discover any damage to the packaging, sign for the goods as "damaged". If you are unable to inspect the goods right away, please ensure you sign for the goods as "unexamined" to allow us to take up any claims with our delivery partners if necessary.
Expected dates and shipping estimates of delivery are approximate. AUDEL shall not be liable for any delays or extra costs in delivery.